CALL: 201-934-9944 / 800-436-3284
Home >
Remote Reboot > iBoot > iBoot-G2

iBoot-G2 Web Controlled Power Switch

  1. General
  2. Operation
  3. Applications
  4. Features
  5. Specifications
  6. Support
iBoot-G2 and iBoot-G2+
 
  • Eliminate Costly Downtime
  • Save on Remote Site Visits
  • Automatically Reboot Crashed Systems
  • Save Energy
  • Keep Your Customers Happy
iBoot-G2 Web Controlled Power Switch application diagram

Remote Reboot via Web Browser

Standard iBoot®



iBoot-G2 is a 10/100 Ethernet network attached, IP addressed, Web Controlled power switch. Anyone with a web browser can access iBoot-G2 to perform power On, Off or Reboot (timed power shutdown). iBoot-G2 is password protected for security.

Remote Power Control from your Web Browser


Just point your browser to iBoot's IP address, enter the Password and you're one click away from power ON, OFF or a timed Reboot.  It's that simple.

Automatic Reboot for Crashed Devices


The unique Auto-Ping feature allows iBoot-G2 to monitor any IP device on the network and take automatic action whenever the device is down.
Read all about Auto-Ping

The new Heartbeat Detect feature allows iBoot-G2 to monitor any server or PC running either the free Heartbeat Generator Program, or heartbeats integrated into your custom software. Dataprobe can provide developer support to make integration easy.   
Find out all about Heartbeat Detector and the Protocol.


A/C and DC Versions


iBoot-G2 for uses international standard IEC320 Connections and is auto sensing for worldwide use. Line cord and Output Cord are included for North America. iBoot-G2 handles circuits up to 12 Amps (10 Amps at 230VAC).

iBoot-DC is auto sensing for 5 - 48 VDC and switches up to 5 Amps (up to 30VDC) and 2 Amps (30VDC and higher)

Wall and DIN Rail Mounting Kit


This kit allows any iBoot-G2 Series unit to be either Wall or DIN Rail Mounted


iBoot-G2 Web Power Switch
Full UL Compliance
iBoot-DC  Network Power Switch DC version

iBoot-DC

Enhanced iBoot®

iBoot-G2+ Remote Reboot Web Power Switch
Full UL Compliance
The iBoot-G2+ provides additional features to expand its capabilities. 2 Expansion-I/O ports that can be used in a variety of ways. It has everything the iBoot-G2 has plus:
  • Expansion to independent control of three outlets
  • General Purpose I/O independently monitored and controlled
  • Heartbeat Monitor - Automatic Failure Detection
  • USB Port for direct PC communication for
    Serial Command Line Interface Access
iBoot-G2+ Expansion Application
Full Compliance
iBoot is UL Listed, FCC, RoHS and WEEE compliant
iBoot-G2 is UL Listed and other products are not. Find out why that is important.
 
Need Remote Reboot of
multiple outlets?
Remote Reboot iBootBar 8 outlet remote power control
iBoot-BAR
Live Demo
 
iBoot Remote Reboot. Demo Camera View

Demo iBoot Remote Power Control now


Cables Included
 
iBoot Remote Reboot. Includes cables for North America
A/C Versions Include All Cables
for North America

Mounting Kit
 
iBoot DC power version.  Remote reboot via web browser.
Wall and DIN
Mounting Kit

Buy Now
 
iboot-g2 Logo
iBoot-G2 Standard Version
$ 179.00
iBoot-DC Standard DC Version
$ 235.00
iBoot-G2+ Logo
iBoot-G2+ Plus Version
$ 199.00
iBoot-EXP Expansion Unit
$ 99.00
Wall/DIN Mounting Kit
$ 8.00
Buy 10 and Save
 
get iboot t-shirt Buy 10 Get This iBoot Shirt!

Larger
10 x iBoot-G2
$ 169.00 ea.
10 x iBoot-G2+
$ 189.00 ea.
Corporate Buyer?
Need a large quantity, modification or OEM/Reseller program?

Click Here

Operation
Simple Web browser control makes iBoot-G2 easy to operate from anywhere.
   
iBoot-G2 Status
iBoot-G2 Status with AutoPing Enabled
View Larger Image   View Larger Image  
   
TCP/IP Setup
Setup - AutoPing Setup
View Larger Image   View Larger Image  
here here too
Applications
  • Routers
  • Kiosks
  • Hot Spots
  • HVAC Generators
  • Servers
  • Cell Sites
  • Signage
  • Alert Systems
Add Expansion and More with iBoot-G2+
Use iBoot-G2 For

Reboot

Remote reboot of any device, routers, servers, kiosks, etc. The device to be rebooted need not be network attached.

Security

Secure sensitive devices by keeping them powered off when not in use. This prevents hackers from detecting them at all times.

Energy Savings

Power down equipment when not needed for power savings and to save on wear and tear.

Notification

Power up alert devices like sirens, lamps, messages.

Control

Power up environmental system like heaters, coolers, pumps, etc
Features
Access from any Network point
No field trips required for Reboot. Save time and money by eliminating service calls and reducing downtime to a minimum.
Web Control
No special software required. Works with any forms capable browser. Easy Web Administration for all configuration.
Dual Password Protected
Separate user and administrator passwords. Deploy iBoots throughout your organization.
IP Addressed, 10/100Base-T
Use on any Ethernet IP network. Public or private. Supports DHCP and alternate ports for Web Access.
Automatic Reboot Operation
Auto-Ping and Heartbeat Detector. Automatic Operation for crashed devices. Auto-Ping pings device while heartbeat listens for periodic message. Complete control over frequency and timers. Developer Assistance and software tools are free.
Learn More
Direct TCP and Software Control
Control iBoot-G2 directly from your software application for the highest degree of power control integration. Simple protocol is freely available. Use iBoot-G2 control program to call power control from any network management system. IPSentry What'sUp Gold, etc.
110/220 VAC Operation
Auto ranging power input. Deploy iBoot-G2 anywhere in the world. iBoot-G2 uses IEC320 Connectors and includes line and extension cords for North America.
12 Amp Switching
Current for most Servers, Routers, Kiosks, etc. 10 Amps at 220 VAC
Specifications
 
iBoot-G2 and iBoot-G2+ A/C Power Version
iBoot-DC DC Power Version
POWER
105 - 240 VAC Auto Ranging
5 - 48 VDC Auto Ranging
POWER SWITCHING
12 Amps at 105-125 VAC, 
10 Amps at  210-240 VAC
5 Amps up to 30 VDC.
2 Amps over 30 VDC
Positive Terminal Switched.
Negative Switched Available on Special Order
POWER CONNECTORS
Power Inlet: IEC 320 C13 Plug.
Linecord for North America Included. 16AWGX3C x 6'/2m
Power Out: IEC 320 C14 Receptacle.
Extension Cord for N. America Included. 16AWGX3C x 2'/60cm
Power Inlet: Screw Terminals

Power Outlet: Screw Terminals

NETWORK
10/100base-T, Auto sensing Uplink/Downlink
Cat 5 Cable Included 6'/2m long

iBoot-G2+ : USB Mini-B Com Port 9600 8 N 1
PROTOCOLS

IP Addressable. DHCP or Static
HTTP Web Server built-in, Port Assignable
Telnet Server built-in, Port Assignable
DxP Messaging Protocol, Port Assignable
Auto-Ping TCP Protocol
Heartbeat Detector Protocol
Download the protocols

External I/O
iBoot-G2+ Only
Two Inputs, Two Outputs, Screw Terminal Connections:

Designator Name Description
V+ Power Out This is +12 VDC power out from the iBoot-G2+
Maximum current 100 mA
I Input Input for status signals. Dry Contact input or Open Collector.
G Ground Signal Ground for Input and Output
O Output 2N3904 NPN Transistor. 100 mA Maximum
BROWSER
Form Processing Browser Required
Netscape 3.0 or IE 3.0 or greater
SECURITY
Dual Password Protected, User and Admin
PHYSICAL
H x W x D: 2.0" x 3.2" x 4.2" (60mm x 82mm x 107mm)
Operating Temperature 0 to 50 Deg. C
RELIABILITY
MTBF 320,000 Hours
Operating Cycles 10,000,000 Mechanical. 100,000 at Maximum Load
COMPLIANCE

AC Versions


UL/cUL UL60950
Listed I.T.E File No. E225914
CE Directives 89/336/EEC, 92/31/EEC and 93/68/EEC
RoHS/WEEE
FCC Part 15 Class B
Support
For Manuals, Downloads and Resources, visit our New iBoot Support Center: Click Here
|
|
|
|
|
|
|
|
|
|


COPYRIGHT © Dataprobe, Inc.

1B Pearl Court, Allendale NJ 07401    Tel: 201-934-9944 / 800-436-3284