iBootBar
Remote Reboot - Power Control - Energy Management - Power Distribution
Reboot Power Strips
Web and DTMF Tone Control in the same unit!
Multi-Outlet, Multi-User Remote Reboot
Outlet Grouping for Simultaneous Switching
Current Sensing and Alarming
Expandable to 128 Outlets
AutoPing for Automatic Failure Detect and Reboot
SNMP Manageability
Full Compliance - UL - CE - FCC
More Features - Lower Price. Your best value in Remote Reboot
Get all the power of the iBoot and more with these remote reboot power strips. Control each outlet independently from Web, Telnet, SNMP. Have network access plus out-of-band control via serial port and internal modem with both data and DTMF tone dial control. Wherever you are, you are in complete control.
iBootBar is available with single or dual power inlets. Dual power is ideal for remote reboot control servers, routers, etc. with redundant power supplies. Simultaneously switch both supplies off and on for reboot, security or energy management. These models are also ideal for switching higher current devices. Each inlet is distributed to 4 outlets, which can be switched in pairs for redundant systems, or individually for higher current devices.
Models are available for North American 15 and 20 amp circuits, as well as international 115/230 VAC, up to 20 amps.
The internal modem option allows connection to the iBootBar from anywhere, anytime. Dial-in with a laptop or terminal for complete control of all functions, or access iBootBar with any telephone for quick power on, off or reboot functions. Telephone users are guided with voice prompts and status information.
iBootBar continuously monitors the current draw from its outlets and reports user settable high and low current alarms. Know immediately when there is too much load, or a device stops working. Alarms are delivered both by email and SNMP traps.
Link up to 16 iBootBars together and control 128 outlets from a single IP address and Web page. Groups and User rights across multiple iBootBars allow power management across your entire network.
iBootBars with 20 Amp ratings require 20 Amp receptacles for power service. Please confirm that you will be able to provide 20 Amp service prior to purchase.
20 Amp Plug on iBootBar looks like this.
Receptacle required for 20 Amp Service looks like this.
Please confirm your requirements prior to purchase.
Operation
Simple Web Browser Power Control
The web browser interface provides the easiest means of managing multiple outlets. One master unit can be connected to 15 expansion units, managing 128 outlets from a single web page interface.
The web page presents a clear status indication of each outlet, current draw across all inputs and the AutoPing monitoring, if implemented.
Each outlet can be individually selected, or multiple outlets can be simultaneously operated. User selectable cycle timer allows single command reboot. Delay timer limits inrush current by staggering power up when multiple devices are simultaneously controlled.
Simple Web Page Control
Multiple Users / Multiple Rights
Up to 15 users can be identified, each with specific rights to one or more outlets, as well as administrator rights for programming the system. User rights can span multiple units, so that one user can command a specific outlet in each of several data cabinets. Users only see the outlets they have rights to.
User rights function the same for both web browser control and the Telnet or serial command line interface.
Multi User Setup
Group Outlets
Two or more outlets can be grouped together for simultaneous action. Link all email servers together to reboot the entire system, or group both power feeds for dual redundant servers, and reboot the server with one command.
Like outlets, groups are individually named and assigned to users as required.
Outlet Group Setup
Control 128 Outlets from 1 IP and Web Page
Link 16 iBootBars together with the Expansion Port and manage 128 outlets from as ingle IP Address and Web Page. Group outlets accross racks to reboot multiple outlet simultaneously.
Assign users rights to similar devices throughout the data center. Use the expansion to conserve IP addresses, or connect each device to the network for additional access capabilities.
Manage Multiple iBootBars
The iBootBar Setup and Control Utility allows simple management of an unlimited number of iBootBars in the field. All configuration parameters can be set, saved, cloned, uploaded and downloaded to or from any iBootBar. This makes it easy to make configuration changes to similar units, or to pre-configure many units prior to deployment.
The Setup and Control Utility also provides secure power management for all outlets deployed worldwide.
Setup and Control Utility
Features
Benefits
Access from any Network point or any Telephone
No field trips required for Reboot. Save time and money
by eliminating service calls and reducing downtime to a
minimum.
Multiple Control Options
Web
Intuitive Browser Interface
Telnet
Complete setup and control access
SNMP
Easy integration into network management systems
Serial
Out-of-band access
Internal Modem
Menu and DTMF dial tones
Multi-User
Assign permissions to each user for outlets and configuration. Users see only outlets assigned
IP Addressed, 10/100Base-T
Use on any Ethernet IP network. Public or private. Supports
DHCP and alternate ports for Web Access.
Automatic Reboot Operation
AutoPing Automatic Operation for crashed devices. AutoPing pings device and takes action when no response. Complete control over frequency and timers.
Current Sensing and Alarms
Know when critical power conditions occur and take immediate action. Email and SNMP Trap notification.
North American and International Versions
115 VAC with N. American cords and plugs.
100-240VAC with IEC connections
Dual and Single Power Inlet
Supports dual redundant powered devices with a single click.
Group and Stagger
Combine any outlets into logical groups and power up devices in sequence to reduce power surges.
Manage 128 Outlets
One IP address and Web Page for up to 128 outlets.
Setup and Control Utility
Save, Clone, Manage multiple configurations. Makes deployment of similar units a snap.
SSL Certificate Utility
Create and deploy SSL Certificates. Self Signed or Root Authority Certificates
Direct TCP Messaging
Integrate iBootBar into your OEM application with direct TCP messaging protocol. Compatibility Mode for original iBB-N15 series products. (requires firmware update to iBootBar Precision. See Resource Tab)
Specifications
PHYSICAL:
Height:
1U 1.75 in (4.5 cm)
Width:
19.0 in (48.25 cm)
Depth:
6.00 in (15.25 cm)
Weight:
7 lbs (3.25 Kg)
Temperature
Operating:
0 to 40 o C
Storage:
-10 to 85 o C
Relative Humidity
0 to 95% Non-Condensing
A/C INPUT
N15 Models
NEMA 5-15 Linecord 115VAC
15 Amps combined total switched per Linecord Supplied with NEMA 5-15 Linecord, attached
N20 Models
NEMA 5-20 Linecord 115VAC 20 Amps combined total switched per Linecord Supplied with NEMA 5-20 Linecord, attached
C10 Models
IEC320 C14 Receptacle 100-240VAC 10 Amps total at 240VAC Max per Linecord Supplied with IEC320 C13 to CEE7 (SHUCO) Linecord
C20 Models
IEC320 C20 Receptacle 100-240VAC 20 Amps total at 240VAC Max per Linecord
Supplied with IEC320 C19 to CEE7 (SHUCO) Linecord
NETWORK
10/100 Ethernet Web, Telnet, SNMP, SMTP
Port Assignable for Web and Telnet. SSL Security on Web control
SERIAL PORT
D9 Serial, configured as DCE. to 115.2Kbps
INTERNAL MODEM
56Kbps V.92 Global Compliance, Data or Tone Dial (DTMF) control
SWITCHED OUTLETS
N15 Models
8 x NEMA 5-15 Receptacle,
12 Amps Max per Receptacle, 15 Amps Max Total per Linecord
N20 Models
8 x NEMA 5-15 Receptacle,
12 Amps Max per Receptacle, 20 Amps Max Total per Linecord
C10 Models
8 x IEC 320-C13
10 Amps Max per Receptacle, 10 Amps Max Total per Linecord
C20 Models
8 x IEC320-C13
10 Amps Max per Receptacle, 20 Amps Max Total per Linecord
COMPLIANCE
UL / cUL Listed
CE Marked
RoHS / WEEE Compliant
FCC Part 15 Class B