$265.00
In stock
If you manage a network with hundreds or thousands of sites, every second of downtime costs you serious amounts of dollars. Our solutions are optimized to help you deploy and manage large scale installations around the world and keep them running with minimal downtime.
iBoot-G2 Status Page
Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events.
Adaptive mobile pages make it easy to make that quick reboot from you smartphone while on the go.
iBoot Cloud Service (iBCS) allows customers with iBoot to access and control multiple iBoots in multiple locations from a single portal with a single sign-on.
iBCS will not only make using iBoots easier, by consolidating all units into one sign-on and interface, it will also enhance the number of situations where iBoot can be deployed.
AutoPing
iBoot automatically monitors and protects your network. AutoPing continuously tests your connectivity to the internet or to any device on your network. When the network is down, or the device stops functioning, iBoot reboots the failed system to get you back on-line fast.
For servers, the Heartbeat service generates a “I’M OK” message from your server to iBoot. When that message disappears, iBoot will reboot the server, using Graceful Shutdown if possible prior to using power off to reboot the crashed system.
Scheduling
With iBoot’s real time scheduler, you can use regular reboots to insure a fresh start each day. Power Up and Down equipment as needed to minimize energy consumption, heat and extend product life. Turn off equipment automatically when not needed for security and access control.
iBoot-G2S and iBoot-G2+ are expandable with low cost satellite units to provide independent control of up to three outlets, with separate AutoPing monitoring as needed. If not used with the expansion units, the ports on the iBoot-G2S can be used as General Purpose I/O or as manual override control for the power outlets.
iBoot-G2+ and -G2S Expansion ports can be used to connect to manual switches or alarm relays for local outlet control. The digital outputs can be use to control external equipment, like a notification lamp or as input to an alarm panel.
Dataprobe Remote Reboot products are UL Listed. This means they are tested by Underwriters Labratories and Certified to meet their exacting standards. It also means that the tests conducted are appropriate for the type of device under test. Only devices that are tested and pass all the tests conducted by UL can apply the UL label.
Dataprobe PDUs are listed under UL 60950-1, and as such are designed for stricter data center environments. Only UL 60950-1 insures that PDUs offer appropriate branch circuit protection.
Other companies use independent labs that test to UL standards. These may or may not be the appropriate safety standards. It is very easy to say tested to UL standards, but that might be for noise emissions or something other than fire safety. Some companies completely forgo safety testing!
Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events. Adaptive mobile pages make it easy to make that quick reboot from you smartphone while on the go.
Dataprobe Remote Reboot products are UL Listed. This means they are tested by Underwriters Labratories and Certified to meet their exacting standards. It also means that the tests conducted are appropriate for the type of device under test. Only devices that are tested and pass all the tests conducted by UL can apply the UL label.
Clean Web page design for immediate status and power control. Auto detects mobile browsers. No special software required.
AutoPing and Heartbeat detect network or equipment outage and takes immediate action to restore your network or device. Real time scheduling to have a fresh reboot each morning or minimize power waste at night.
Manage all your iBoots from a single sign-on. Control power worldwide from any web browser, anytime anywhere.
Attempts to do a Graceful Shutdown or Restart on Windows platforms prior to hard power switch.
Add one or two iBoot-EXP expansion units with independent control, and AutoPing. When not used for expansion units, the inputs and outputs can be used for general purpose I/O or as manual power control.
Out-of-band management with simple serial commands for status, control and setup.
We take your safety seriously. Be confident to pass fire marshal and OSHA inspections.
Clean web page design makes it easy to see the status and control power to any outlet. History log shows the last 5 events. If AutoPing or Heartbeat are enables, their status is displayed as well.
All the setup is handled with easy web forms. Set multiple schedules to have a clean reboot every morning, or shut down at night to reduce power waste.
Take power control with you wherever you travel. iBoot Automatically detects mobile browsers and provides reduced clutter for easy one thumb access.
10/100base-T, Auto sensing Uplink/Downlink Cat 5 Cable Included 6’/2m long
USB Mini-B Com Port 9600 8 N 1
IP Addressable. DHCP or Static HTTP Web Server built-in, Port Assignable Telnet Server built-in, Port Assignable DxP Messaging Protocol, Port Assignable Auto-Ping TCP Protocol Heartbeat Detector Protocol
Designator | Name | Description |
V+ | Power Out | This is +12 VDC power out from the iBoot-G2+ Maximum current 100 mA |
I | Input | Input for status signals. Dry Contact input or Open Collector. |
G | Ground | Signal Ground for Input and Output |
O | Output | 2N3904 NPN Transistor. 100 mA Maximum |
Form Processing Browser Required Mozilla 3.0 or IE 3.0 or greater
Dual Password Protected, User and Admin
H x W x D: 2.0″ x 3.2″ x 4.2″ (60mm x 82mm x 107mm) Operating Temperature 0 to 50 Deg. C
MTBF 320,000 Hours Operating Cycles 10,000,000 Mechanical. 100,000 at Maximum Load
RoHS/WEEE FCC Part 15 Class B AC Versions UL/cUL UL60950 Listed I.T.E File No. E225914 CE Directives 89/336/EEC, 92/31/EEC and 93/68/EEC